Overview:
Sepragen chromatograph is widely used in the separation and purification of biological macromolecules, has served more than 40 FDA approved drug research and development projects, effectively support radial chromatography process, the application range covers lab, pilot, production scale purification research, fully meet customer needs.
Products are divided into 3 series according to their characteristics.
1) QuantaSep Trusty Series:
General configuration series.
2) QuantaSep Adept two-channel series:
A set of chromatograph is configured with 2-3 sets of flow paths, and users can switch between lab, pilot and production scale according to actual needs, which is equivalent to 2-in-1 or 3-in-1 models.
3) QuantaSep Adept single use:
In order to avoid the trouble of cleaning and cleaning verification, the single use flow path SU (Single Use) series is designed. The flow path design of the system is flexible and can be disassembled for easy cleaning and disinfection.
All series meet the requirements of cGMP production conditions, all support the sample forward, reverse and bypass 3 inflow modes, so that the product and the resin more fully combined. There is also a unique pre-filtration function, automatic bubble eject function and leakage monitoring function to make the purification process more efficient. QuantaSep software complies with 21CFR, Part11, automatically generates GMP reports.QuantaSep Adept(part of representative products)
Catalog #
Description
70-0300-00AS
QuantaSep Adept 300 also known as the QuantaSep 300 SU Chromatography System (with 2
flow paths, 0 – 100 mL/min flowrate range and 10mL/min – 300ml/min flow
range).
Includes
all post-column sensors (UV 280nm and 254nm (0-2AU range), pH, Conductivity
(0-300mS range)), Pressure, Air and Leak sensors,
dual
pumps for gradients, 2 pumps, 12 buffer Inlets (6 inlets connected to each
pump), 1 Column Forward, Reverse & Bypass Valves, and 6 Fraction Valves,
and computer and software. Included is 1 non-sterile flow path
70-3000-00AS
QuantaSep Adept 3000 also known as the QuantaSep 3000 SU Chromatography System (with 3
flow paths, 3.2mm with 0 – 300 mL/min flowrate range and 6.4mm with 80 –
1500ml flow range and 9.6mm with 130mL/min – 3000ml/min flow range).
Includes
all post-column sensors (UV 280nm and 254nm (0-2AU range), pH, Conductivity
(0-300mS range)), Pressure, Air and Leak sensors, dual pumps for gradients, 2
flowmeters, 8 buffer Inlets, Column Forward, Reverse & Bypass Valves, and
6 Fraction Valves, and computer and software. Included is 1 non-sterile flow
path
Order list:
Catalog
#
Description
70-0300-00AS
• The built-in chromatographic
pipeline is a sterile sanitation pipeline, and the pipeline can be replaced
after the completion of the production task, without cleaning verification
• With 2 sets of flow paths,
0-100 mL/min low flow rate and 10mL/ min-300 ml/min high flow rate.
70-3000-00AS
•
The built-in chromatographic pipeline is a sterile sanitation pipeline, and
the pipeline can be replaced after the completion of the production task,
without cleaning verification
•
With 3 sets of flow paths, 0-300 mL/min, 80-1500mL /min and 130-3000mL /min.
70-3000-P0AS
Model
70-3000-00AS with column front sensor
70-3000-F0AS
Models
70-3000-00AS are equipped with flowmeters
70-3000-PFAS
Models
70-3000-00AS are equipped with column front sensors and flowmeters
70-5000-00AS
The
QuantaSep Adept 5000 is also known as the QuantaSep 5000 SU chromatography
system
•
The built-in chromatographic pipeline is a sterile sanitation pipeline, and
the pipeline can be replaced after the completion of the production task,
without cleaning verification
•
Flow rate 50-5000 mL/min
•
Dual pump gradient elution can be performed
•8
Selectable buffer ports
•3
selectable column flow directions, forward/reverse/bypass modes,
•
Dual UV (280nm, 254nm), conductivity, temperature, pH, pressure, air sensor
•6
selectable sample collection ports, compliant with GMP design
70-10000-00AS
QuantaSep Adept10000
is also known as the QuantaSep 10000 SU chromatography system
•
The built-in chromatographic pipeline is a sterile sanitation pipeline, and
the pipeline can be replaced after the completion of the production task,
without cleaning verification
•
Flow rate 50-10000 mL/min
•
Dual pump gradient elution can be performed
•8
Selectable buffer ports
•3
selectable column flow directions, forward/reverse/bypass modes,
•
Dual UV (280nm, 254nm), conductivity, temperature, pH, pressure, air sensor
•6
selectable sample collection ports, compliant with GMP design
70-16000-00AS
QuantaSep Adept16000
is also known as the QuantaSep 16000 SU chromatography system
•
The built-in chromatographic pipeline is a sterile sanitation pipeline, and the
pipeline can be replaced after the completion of the production task, without
cleaning verification
•
Flow rate 50-16000 mL/min
•
Dual pump gradient elution can be performed
•8
Selectable buffer ports
•3
selectable column flow directions, forward/reverse/bypass modes,
•
Dual UV (280nm, 254nm), conductivity, temperature, pH, pressure, air sensor
•6
selectable sample collection ports, compliant with GMP design
70-30000-00AS
QuantaSep Adept30000
is also known as the QuantaSep 30000 SU chromatography system
•
The built-in chromatographic pipeline is a sterile sanitation pipeline, and
the pipeline can be replaced after the completion of the production task,
without cleaning verification
•
Flow rate 50-30000 mL/min
•
Dual pump gradient elution can be performed
•8
Selectable buffer ports
•3
selectable column flow directions, forward/reverse/bypass modes,
•
Dual UV (280nm, 254nm), conductivity, temperature, pH, pressure, air sensor
70-60000-00AS
QuantaSep Adept60000
is also known as the QuantaSep 60000 SU chromatography system
•
The built-in chromatographic pipeline is a sterile sanitation pipeline, and
the pipeline can be replaced after the completion of the production task,
without cleaning verification
•
Flow rate 50-60000 mL/min
•
Dual pump gradient elution can be performed
•8
Selectable buffer ports
•3
selectable column flow directions, forward/reverse/bypass modes,
•